| JET VENTURI FUME SCRUBBER |
| |
- Principles of Operation
- Ejector design utilizes a well atomized scrubbing liquid stream to entrain contaminated gas stream
- High Liquid/Gas ratio and surface area provided by the atomized liquid provides effective absorption of toxic gases
- Large number of small droplets provides efficient capture of particulate (even at heavy loadings) to approx. 2 micron size
|
 |
- Typical Operating Parameters
- Liquid/Gas Ratio = 40 - 100 gpm/1000 cfm
- Spray Nozzle Pressure Drop = 15 - 100 psi
- Suction Draft = 0 - 3” w.c.
|
| Typical Jet Venturi Fume Scrubber Performance |
| |
|
|
|
|
- Maleic Anhydride 85 - 90%
|
|
- Silicon Tetrachloride 90%
|
Click Here to Download PDF  |
| |
|